{"@context":"http://iiif.io/api/presentation/4/context.json","id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/manifest","type":"Manifest","label":{"ja":["L・ジュリアン・ヘイウッド博士が開発したデジタル心拍リズムモニターの試作機"],"en":["Prototype of a digital heart rhythm monitor developed by Dr. L. Julian Haywood"]},"summary":{"ja":["デジタル心拍リズムモニタリングは、心臓発作患者の心拍リズム異常を検出する目的で、先駆的なアフリカ系アメリカ人の心臓専門医L・ジュリアン・ヘイウッド医学博士とその同僚たちによって開発された。この技術は、ヘイウッド博士が1966年に設立した西海岸初の施設であるロサンゼルス郡総合病院の冠動脈疾患集中治療室（CCU）において、1969年に開発され初めて導入された。物理的なコンソールと関連ソフトウェアは、ヘイウッド博士の仕様に基づいて現地で開発された。"],"en":["Digital heart rhythm monitoring was developed for the purpose of detecting heart rhythm abnormalities in heart attack patients by pioneering African American cardiologist L. Julian Haywood, M.D., and his associates. The technology was developed and first implemented in 1969 in the Coronary Care Unit at L.A. County General Hospital, the first such facility on the west coast, established by Dr. Haywood in 1966. The physical console and related software were developed on-site to Dr. Haywood’s specifications."]},"metadata":[{"label":{"ja":["分野"],"en":["Topic"]},"value":{"ja":["医学"],"en":["Medicine"]}},{"label":{"ja":["museum"]},"value":{"ja":["国立アフリカ系アメリカ人歴史文化博物館"],"en":["National Museum of African American History and Culture"]}},{"label":{"ja":["objectType"]},"value":{"ja":["モニター"],"en":["monitors (data processing equipment)"]}},{"label":{"ja":["日付"],"en":["Date"]},"value":{"ja":["1966〜1969年"]}},{"label":{"ja":["作成者"],"en":["Creator"]},"value":{"ja":["L・ジュリアン・ヘイウッド医学博士（L. Julian Haywood, M.D., American, 1927 - 2020）"],"en":["L. Julian Haywood, M.D., American, 1927 - 2020"]}}],"rights":"http://creativecommons.org/publicdomain/zero/1.0/","thumbnail":[{"id":"https://3d-api.si.edu/content/document/3d_package:f2d0d103-24d5-4ec5-a768-b983873ea1f1/scene-image-low.jpg","type":"Image","format":"image/jpeg"}],"homepage":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/item/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1","type":"Text","label":{"ja":["詳細ページ"],"en":["Detail page"]},"format":"text/html"},{"id":"https://nmaahc.si.edu/object/nmaahc_2017.42","type":"Text","label":{"ja":["出典"],"en":["Source"]},"format":"text/html"}],"rendering":[{"id":"https://3d-api.si.edu/content/document/3d_package:f2d0d103-24d5-4ec5-a768-b983873ea1f1/heartmonitor_wrapCombineStitch_MshlabDecimate_RZunwrap_BlenderBake-150k-2048-medium.glb","type":"Model","label":{"ja":["3Dモデル (GLB)"],"en":["3D model (GLB)"]},"format":"model/gltf-binary"}],"items":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1","type":"Scene","label":{"ja":["L・ジュリアン・ヘイウッド博士が開発したデジタル心拍リズムモニターの試作機"],"en":["Prototype of a digital heart rhythm monitor developed by Dr. L. Julian Haywood"]},"backgroundColor":"#000000","items":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1/page","type":"AnnotationPage","items":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1/model","type":"Annotation","motivation":"painting","body":{"id":"https://3d-api.si.edu/content/document/3d_package:f2d0d103-24d5-4ec5-a768-b983873ea1f1/heartmonitor_wrapCombineStitch_MshlabDecimate_RZunwrap_BlenderBake-150k-2048-medium.glb","type":"Model","format":"model/gltf-binary"},"target":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1"}]}],"annotations":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1/annotations","type":"AnnotationPage","items":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1/annotation/AR7VJhf8ahM0","type":"Annotation","motivation":["commenting"],"body":{"type":"TextualBody","value":"この試作デジタル心臓モニターにより、1人の看護師が同時に4人の患者を監視できた。左上の4つのソケットに接続された配線は冠動脈疾患集中治療室（CCU）の個々の患者につながっており、モニター自体は部屋一つ分の大きさのコントロール・データ・コーポレーション製コンピューターに接続されていた。","label":"4つのソケット","language":"ja","format":"text/plain"},"target":{"type":"SpecificResource","source":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1","type":"Scene"}],"selector":[{"type":"PointSelector","x":-0.118059,"y":0.2079852,"z":-0.0687376,"normal":[0.0111723,0.9984504,0.0545166]}]}},{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1/annotation/s8aaVz71RSu0","type":"Annotation","motivation":["commenting"],"body":{"type":"TextualBody","value":"左側パネルの色付きランプは、患者につながった回線が正常な心拍リズムを示しているとき（緑）、異常な心臓イベントがあるとき（黄）、警報が発せられているとき（赤）を示す。","label":"色付きのランプ","language":"ja","format":"text/plain"},"target":{"type":"SpecificResource","source":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1","type":"Scene"}],"selector":[{"type":"PointSelector","x":-0.1769699,"y":0.1243845,"z":0.0488106,"normal":[-0.2525865,0.7662511,0.5908124]}]}},{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1/annotation/s77yb8iuS7KJ","type":"Annotation","motivation":["commenting"],"body":{"type":"TextualBody","value":"右側の3列のダイヤルにより、スタッフは4人の患者それぞれの心電図パルスを記録・比較するための個別のパラメータを設定できた。","label":"ダイヤル","language":"ja","format":"text/plain"},"target":{"type":"SpecificResource","source":[{"id":"https://archivebase.ldas.jp/na-kamura-1263/smithsonian-3d/api/iiif/4/prototype-of-a-digital-heart-rhythm-monitor-developed-by-dr--f2d0d1/scene/1","type":"Scene"}],"selector":[{"type":"PointSelector","x":0.1472924,"y":0.1148391,"z":0.2147328,"normal":[-0.2861651,0.8050986,0.5195438]}]}}]}]}]}